AMCO AL800-5000 Diaphragm Meter |
|
|
|
|
|
|
|
|
File Name:
AMCO-AL800-5000 |
File Size: 1.42 MB |
|
|
|
|
General Information
|
|
|
AL800-5000 Commercial and industrial Aluminum case Diaphragm Meters Capacity Ratings from 800 scfh to 5000 scfh.
American Meter's compact, lightweight, aluminum case meters are designed to provide positive displacement accuracy for industrial or commercial loads. The one-piece aluminum alloy body, top and covers provide durability and high resistance to impact damage.
Each model incorporates refinements in design and materials pioneered by American Meter to give the best in-service performance at lowest maintenance costs.
To eliminate lost revenue from inaccurate measurement of gas volumes due to temperature changes, American meter is available with temperature compensation.
|
|
|
|
|
|
Pressure Rating |
|
|
AL-800 and AL-1000 Aluminum case Diaphragm Meters
Meter Model MAOP |
AL-800 |
AL-1000 |
Inlet
Pressure (psig) |
Differential
Pressure (in. w. c.) |
20 psig |
100psig |
25 psig |
100 psig |
Meter Capacity (scfh) For 0.60 S .G. Gas |
0.25
0.25
5 |
1/2
2
2 |
800
1,700
2,100 |
800
1,700
2,100 |
1,000
2,200
2,700 |
1,000
2,200
2,700 |
10
15
20 |
2
2
2 |
2,600
2,800
3,200 |
2,600
2,800
3,200 |
3,400
3,700
4,100 |
3,400
3,700
4,100 |
25
30
50 |
2
2
2 |
-
-
- |
3,500
3,800
5,100 |
4,600
-
- |
4,600
5,000
6,600 |
75
100 |
2
2 |
-
- |
6,500
7,800 |
-
- |
8,400
10,100 |
Cubic Feet Per Revolution |
5/13 |
Proving Circle Volume (English) |
5 ft 3 or 10 ft 3 |
Proving Circle Volume (Metric) |
0.1m 3 |
Undergear Ratio(English) |
13:1( 5 ft 3 ) or 26:1 ( 10 ft 3 ) |
Undergear Ratio(Metric) |
9:1 |
Installation Instructions Bulletin |
IM 3701 |
Parts List Bulletin |
RPL 3807 |
AL-1400 Aluminum case Diaphragm Meters
Meter Model MAOP |
AL-1400 |
Inlet
Pressure (psig) |
Differential
Pressure (in. w. c.) |
100 psig |
Meter Capacity (scfh) For 0.60 S. G. Gas |
0.25
0.25
5 |
1/2
2
2 |
1,400
3,000
3,700 |
10
15
20 |
2
2
2 |
4,600
5,000
5,600 |
25
30
50 |
2
2
2 |
6,200
6,800
9,000 |
75
100 |
2
2 |
11,500
13,800 |
Cubic Feet Per Revolution |
5/7 |
Proving Circle Volume (English) |
5 ft 3 or 10 ft 3 |
Proving Circle Volume (Metric) |
0.1m 3 |
Undergear Ratio(English) |
7:1( 5 ft 3 ) or 14:1 ( 10 ft 3 ) |
Undergear Ratio(Metric) |
5:1 |
Installation Instructions Bulletin |
IM 3701 |
Parts List Bulletin |
RPL 3808 |
AL-2300 Aluminum case Diaphragm Meters
Meter Model MAOP |
AL-2300 |
Inlet
Pressure (psig) |
Differential
Pressure (in .w. c.) |
100 psig |
Meter Capacity (scfh) For 0.60 S. G. Gas |
0.25
0.25
5 |
1/2
2
2 |
2,300
5,000
6,200 |
10
15
20 |
2
2
2 |
7,700
8,400
9,400 |
25
30
50 |
2
2
2 |
10,400
11,400
15,000 |
75
100 |
2
2 |
19,100
23,000 |
Cubic Feet Per Revolution |
1-1/4 |
Proving Circle Volume (English) |
10 ft 3 or 100 ft 3 |
Proving Circle Volume (Metric) |
0.1m 3 or 1.0m 3 |
Undergear Ratio(English) |
8:1( 100 ft 3 ) or 80:1 ( 100 ft 3 ) |
Undergear Ratio(Metric) |
2:8:10.( 0.1m 3 ) or 28:1( 1.0m 3 ) |
Installation Instructions Bulletin |
IM 3701 |
Parts List Bulletin |
RPL 3809 |
AL-5000 Aluminum case Diaphragm Meters
Meter Model MAOP |
AL-5000 |
Inlet
Pressure (psig) |
Differential
Pressure (in .w .c.) |
100 psig |
Meter Capacity (scfh) For 0.60 S. G. Gas |
0.25
0.25
5 |
1/2
2
2 |
5,000
11,000
13,500 |
10
15
20 |
2
2
2 |
17,000
18,500
20,600 |
25
30
50 |
2
2
2 |
23,000
25,000
33,000 |
75
100 |
2
2 |
42,000
50,500 |
Cubic Feet Per Revolution |
2-6/7 |
Proving Circle Volume (English) |
10 ft 3 or 100 ft 3 |
Proving Circle Volume (Metric) |
1.0m 3 |
Undergear Ratio(English) |
3.5:1( 100 ft 3 ) or 35:1 ( 100 ft 3 ) |
Undergear Ratio(Metric) |
12.3:1 |
Installation Instructions Bulletin |
IM 3701 |
Parts List Bulletin |
RPL 3810 |
|
|
|
|
|
|
A Complete Family of Gas Measurement, Pressure Regulation, and Testing Systems
Turbine Gas Meters
High-performance meters provide accurate measurement of high-volume gas flow. Turbines are available from 3กจ to 12กจ line sizes and line pressures up to 1440 psig.
Electronic Instruments
Electronic correction of temperature or pressure or both at the meter . Data can be accessed via the unit's display, downloaded to a personal computer or transmitted via modern.
Pressure Regulators
Inlet-and outlet-pressure regulators with a wide range of capacities. These regulators have optional overpressure and underpressure shutoff and full-capacity internal relief.
Test Apparatus
SNAP-The Sonic Nozzle Auto Prover provides unparalleled speed and accuracy in gas-meter proving.
|
|
|
|
|
|
|
|
|
|